Errors, timeouts and cancellation
Hyper Compress has four error codes, and every surface reports them in its own way. This guide shows how to catch each one, which results look unusual but are not errors, how to put a time limit on a job, and how to stop one that is running.
Before you begin
- Install Hyper and compress one file first. See the Quickstart.
- Time limits and cancellation are fullest in the Node.js SDK and the Rust crate. The HTTP API has a time limit; the CLI has a fixed one; the WebAssembly SDK and the C API have neither.
The four error codes
| Code | Meaning | Retry? |
|---|---|---|
decrypt_failed | The input is encrypted and the password is wrong, or it needs a password and you sent none. | No. Ask for the right password. Retrying with the same one fails the same way. |
engine_error | Hyper could not run: the input file is missing or unreadable, the input is not a PDF, the output cannot be written, an engine binary is missing, or sourcePath is empty. The message says which. | No, not until you fix the cause in the message. |
timeout | One stage ran longer than its stage limit, or the whole call ran longer than its total limit. | Yes, with a longer limit or lighter settings. |
cancelled | You cancelled the call. | Only if you still want the result. |
A broken or unusual PDF is usually not an error. If the engine cannot process a file that starts like a PDF, Hyper falls back to repacking it or to your original bytes, and the call succeeds. See Outcomes that are not errors.
1. Catch errors on your surface
hyper locked.pdf output.pdf --password hunter2
echo "exit code: $?"import { compress, HyperError } from 'hyper-compress';
try {
await compress({ sourcePath: 'locked.pdf', savePath: 'output.pdf', password: 'hunter2' });
} catch (e) {
if (!(e instanceof HyperError)) throw e;
switch (e.code) {
case 'decrypt_failed': console.error(e.message); break;
case 'timeout': console.error('took too long'); break;
case 'cancelled': console.error('cancelled'); break;
default: console.error('cannot run:', e.message);
}
}curl -s -o output.pdf -w '%{http_code}\n' --data-binary @locked.pdf \
-H 'X-Password: hunter2' \
'http://localhost:8080/api/compress'
cat output.pdfimport { readFile, writeFile } from 'node:fs/promises';
import { compress, HyperError } from 'hyper-compress-wasm';
const input = new Uint8Array(await readFile('locked.pdf'));
try {
const result = await compress(input, { password: 'hunter2' });
await writeFile('output.pdf', result.data);
} catch (e) {
if (!(e instanceof HyperError)) throw e;
console.error(e.code, e.message);
}use hyper_compress::{compress, Binaries, CompressInput, ErrorCode};
fn main() {
let input = CompressInput {
source_path: "locked.pdf".into(),
save_path: Some("output.pdf".into()),
password: Some("hunter2".into()),
binaries: Binaries::beside_exe(),
..Default::default()
};
match compress(&input) {
Ok(r) => println!("{} -> {} bytes", r.original_size, r.compressed_size),
Err(e) if e.code == ErrorCode::DecryptFailed => eprintln!("{}", e.message),
Err(e) => eprintln!("{}: {}", e.code.as_str(), e.message),
}
}int rc = hpdf_compress_file("locked.pdf", "output.pdf", NULL, NULL, 0, "hunter2");
if (rc == 1) fprintf(stderr, "failed: %s\n", hpdf_last_error());What each surface reports when hunter2 is not the file's password. Leaving the password out of a file that needs one fails the same way, with the message the PDF is encrypted and needs a password. A file that has only an owner password (one that restricts editing or printing) still compresses without a password, and the output keeps that protection.
| Surface | What you get |
|---|---|
| CLI | error: decrypt_failed on stderr, exit code 1 |
| Node.js | HyperError with code 'decrypt_failed' |
| HTTP | status 400, body {"error":"decrypt_failed"} |
| WebAssembly | HyperError with code 'decrypt_failed' |
| Rust | Err(HyperError) with code ErrorCode::DecryptFailed |
| C | return code 1, and hpdf_last_error() describes it, for example cannot open input (missing, corrupt, or wrong password) |
How each surface exposes the codes
CLI. Exit code 0 means a file was written, 1 means an error, 2 means bad usage (an unknown flag or a missing input path). On an error the CLI prints one line to stderr that starts with error:, for example error: decrypt_failed, error: the PDF is encrypted and needs a password or error: the input is not a PDF: no %PDF- header in its first 1024 bytes. Usage errors print the usage text after the error: line.
Node.js. compress rejects with a HyperError. e.code is one of the four codes and e.message adds detail, such as the platform name when no engine binary exists, or which stage ran out of time. verifyPassword uses the same codes: it returns false for a wrong password, and throws engine_error when the file is missing and timeout when the check runs past its limit (60 seconds unless you pass one).
HTTP. Errors come back as JSON with an error field and a status code:
| Status | error | When |
|---|---|---|
| 400 | decrypt_failed | the password does not open the file, or the file needs one and none was sent |
| 500 | engine_error | Hyper could not run |
| 500 | cancelled | the job was stopped |
| 504 | timeout | the job ran past HYPER_TIMEOUT_MS |
Send the password in X-Password when it is plain ASCII, or percent-encoded (as JavaScript encodeURIComponent does) in X-Password-Encoded for any other characters. The API also has request errors that never reach the engine, such as 400 not_a_pdf, 413 too_large and 429 busy. The HTTP API reference lists them all.
WebAssembly. compress rejects with a HyperError whose code is only ever decrypt_failed or engine_error. engine_error also covers input that is not a PDF and a WebAssembly module that failed to load; the next call tries to load it again. The WebAssembly SDK has no time limit and no cancellation, so timeout and cancelled never occur.
Rust. compress returns Result<CompressResult, HyperError>. HyperError has code (an ErrorCode: DecryptFailed, EngineError, Timeout or Cancelled, with as_str() for the string form) and message.
C. hpdf_compress_file returns 0 (compressed), 2 (signed input, copied unchanged) or 1 (failed). hpdf_compress_buffer returns NULL on failure and sets *out_status to 1. After a failure, hpdf_last_error() returns one of: cannot open input (missing, corrupt, or wrong password), cannot parse input (corrupt or wrong password), engine pass failed, cannot open output for writing, save failed, input larger than 2 GB is not supported. The C API is the engine pass alone, so it has no timeout or cancelled, and it does not fall back to your original file.
2. Recognise outcomes that are not errors
These results succeed (exit code 0, HTTP 200, no exception). Check for them in your code if they matter to you.
| Outcome | How to spot it |
|---|---|
| No gain: Hyper could not make the file smaller and returned your original bytes | compressedSize equals originalSize; the CLI prints 0% smaller |
| Signed input returned untouched | signed: true; CLI [signed: original preserved]; HTTP X-Signed: true; C return code 2 |
| Size target missed; you got the smallest file Hyper could make | metTarget: false; CLI [target NOT met - best effort]; HTTP X-Met-Target: false |
| An option was skipped because it was unsafe for this file | an entry in warnings; CLI warning: lines on stderr; HTTP X-Warnings header |
| A broken PDF the engine could not process | a valid result, usually your original bytes |
import { compress } from 'hyper-compress';
const r = await compress({ sourcePath: 'input.pdf', savePath: 'output.pdf', targetSizeBytes: 2 * 1024 * 1024 });
if (r.signed) console.log('signed: returned untouched');
if (r.compressedSize === r.originalSize) console.log('no gain: original kept');
if (r.metTarget === false) console.log(`target missed, best was ${r.compressedSize} bytes`);
for (const w of r.warnings) console.warn('skipped:', w);Every warning text is listed in Warnings.
3. Put a time limit on a job
A compression runs as a series of stages, each in its own process: decryption (only with a password), the engine pass, and a repack. A size target runs the engine pass and repack again for each attempt, and a report adds two read passes.
Hyper has two kinds of limit. Both stop the work and fail the call with timeout:
| Limit | Default | Message when it runs out |
|---|---|---|
Per stage (timeoutMs) | 600000 (10 minutes) | names the stage, for example the engine pass ran longer than the 600000 ms stage limit (other stages are decryption and qpdf) |
Whole call (totalTimeoutMs) | none | timeout |
The per-stage limit catches one stuck step. The total limit bounds the whole call, which matters with a size target, where many stages run one after another.
import { compress, HyperError } from 'hyper-compress';
try {
await compress({
sourcePath: 'input.pdf',
savePath: 'output.pdf',
totalTimeoutMs: 2 * 60 * 1000,
});
} catch (e) {
if (e instanceof HyperError && e.code === 'timeout') console.error('gave up after 2 minutes');
else throw e;
}docker run -d --name hyper -p 8080:8080 \
-e HYPER_TIMEOUT_MS=120000 \
ghcr.io/alam00000/bentopdf-hyper-compress:latestuse std::time::Duration;
use hyper_compress::{compress, Binaries, CompressInput, ErrorCode};
fn main() {
let input = CompressInput {
source_path: "input.pdf".into(),
save_path: Some("output.pdf".into()),
total_timeout: Some(Duration::from_secs(120)),
binaries: Binaries::beside_exe(),
..Default::default()
};
match compress(&input) {
Ok(r) => println!("{} -> {} bytes", r.original_size, r.compressed_size),
Err(e) if e.code == ErrorCode::Timeout => eprintln!("gave up after 2 minutes"),
Err(e) => eprintln!("{}", e.message),
}
}With a total limit of 2 minutes, a job that runs longer fails with:
gave up after 2 minutesHow each surface sets the limits:
| Surface | Per stage | Whole call |
|---|---|---|
| Node.js | timeoutMs | totalTimeoutMs |
| Rust | stage_timeout | total_timeout |
| HTTP | HYPER_TIMEOUT_MS (default 600000) | HYPER_TIMEOUT_MS, the same value |
| CLI | fixed at 10 minutes; prints error: ... stage limit and exits 1 | none |
| WebAssembly | none | none |
| C | none | none |
Over HTTP the one setting is used for both, so a job that runs past HYPER_TIMEOUT_MS gets status 504 with {"error":"timeout"}. Allowed values are 1 second to 24 hours. See Self-hosting.
4. Cancel a running job
In Node.js, pass an AbortSignal. Aborting before the call starts rejects at once without running anything. Aborting while it runs stops the engine process that is working and rejects with cancelled.
import { compress, HyperError } from 'hyper-compress';
const controller = new AbortController();
setTimeout(() => controller.abort(), 5000);
try {
await compress({ sourcePath: 'input.pdf', savePath: 'output.pdf', signal: controller.signal });
} catch (e) {
if (e instanceof HyperError && e.code === 'cancelled') console.log('cancelled after 5 seconds');
else throw e;
}use std::thread;
use std::time::Duration;
use hyper_compress::{compress, Binaries, CancelToken, CompressInput, ErrorCode};
fn main() {
let cancel = CancelToken::new();
let input = CompressInput {
source_path: "input.pdf".into(),
save_path: Some("output.pdf".into()),
cancel: cancel.clone(),
binaries: Binaries::beside_exe(),
..Default::default()
};
let job = thread::spawn(move || compress(&input));
thread::sleep(Duration::from_secs(5));
cancel.cancel();
match job.join().expect("compress thread panicked") {
Err(e) if e.code == ErrorCode::Cancelled => println!("cancelled after 5 seconds"),
Err(e) => eprintln!("{}", e.message),
Ok(r) => println!("finished first: {} bytes", r.compressed_size),
}
}cancelled after 5 secondsHyper checks for cancellation every few milliseconds while a stage runs, so the call stops quickly even in the middle of a large file. No output file is written for a cancelled call.
Cancellation on the other surfaces:
| Surface | Cancellation |
|---|---|
| CLI | Ctrl+C stops the command. |
| HTTP | None. A client that disconnects does not stop its job; the job runs to the end or to HYPER_TIMEOUT_MS. |
| WebAssembly | None. To stop a run, run it in a worker thread and terminate the thread. |
| C | None. |
How it works
- The engine runs in its own process. On the native surfaces (CLI, Node.js, HTTP, Rust), each stage is a separate process. If a malformed PDF crashes the engine, only that process ends; your application keeps running and Hyper falls back to the best file it has. If it hangs, the stage limit stops it and the call fails with
timeout. - Corrupt input degrades, it does not throw. A file that starts like a PDF but cannot be read comes back as your original bytes. Hyper's test suite checks this.
- A failed call leaves no output. The output is written to a temporary file beside the destination and renamed into place at the end, so a failed or cancelled call never leaves a half-written file. This also makes it safe to use the input path as the output path.
Troubleshooting
decrypt_failed with the right password. Check it first with verifyPassword (Node.js and WebAssembly) or POST /api/verify-password (HTTP). The PDF may have a different user password from the one you have. Only the first line of a password is used. Over HTTP, send a password with non-ASCII characters in X-Password-Encoded.
engine_error: no hpdf-worker binary for <platform>. There is no native build for this platform. Use the WebAssembly SDK, or build from source and set HYPER_DRV. See Platforms.
engine_error: cannot read input.pdf: No such file or directory (os error 2). The input path is wrong. If the input is fine, check that the folder of the output path exists.
engine_error: hpdf-worker not found at <path> (or qpdf not found at <path>). HYPER_DRV or HYPER_QPDF points at a file that does not exist. Fix the path or unset the variable.
engine_error: the input is not a PDF. The file has no %PDF- header in its first 1024 bytes. Over HTTP the same file gets 400 not_a_pdf.
timeout with ran longer than the ... ms stage limit. One stage ran past timeoutMs. Raise timeoutMs, or use lighter settings (for example speed: 'fast').
HTTP returns 504. The job ran past HYPER_TIMEOUT_MS. Raise it, or send lighter settings.
Next steps
- Errors: every error code and message in one place.
- Warnings: every warning Hyper can return.
- Running in production: concurrency, queues and untrusted uploads.